The problem: Massive tears have the highest failure rates
Many surgeons and their patients would prefer rotator cuff repair over joint replacement. Even with advances in rotator cuff repair techniques and technology in recent years, tissue quality, biomechanical forces and lack of a good vascular supply1,2,3,4 have led to reported failure rates of as high as 68%1 in large to massive tears (Grades III and IV). However, surgeons who use a biologic scaffold and innovative anchors like the Y-Knot RC are achieving higher success rates while still preserving the joint.2,4
The solution: Augment the repair with an Extracellular Matrix (ECM) scaffold
In large tears and revisions, poor tissue quality is one of the biggest obstacles to performing a successful repair. By augmenting the tissue with an ECM scaffold like Allopatch HD®, peer reviewed research has shown that surgeons can potentially go from a 40%2 success rate without augmentation to an 85.7%4 success rate with augmentation.
Among the available scaffold types, clinical studies have shown that ECMs like Allopatch HD® are stronger – exhibiting better suture retention and greater ultimate load failure rates than synthetics and xenografts.3
Take the uncertainty out of choosing the right ECM with Allopatch HD®
Unlike other ECMs that need to be hydrated for 60 minutes or longer before being used – delaying completion of the procedure and prolonging OR time – Allopatch HD requires no refrigeration or rehydration and it is ready to use off the shelf almost immediately.
Allopatch HD is minimally processed and not crosslinked which better preserves and maintains the graft’s natural biomechanical, biochemical and matrix properties.
While it is often assumed that all allograft tissue is the same, tissue quality can actually vary greatly depending on the standards of the tissue bank. MTF Biologics, the tissue bank that supplies CONMED the allograft tissue, has some of the most stringent donor selection standards of any tissue bank in the world, which allows MTF Biologics to process aseptically, thus preserving the tissues natural biomechanical and biochemical properties.
NEW! Y-Knot® PRO
The Y-Knot® PRO combines the Y-Knot® anchor with a new, cleatless suture release technology. The Y-Knot® PRO:
Allopatch HD®
Y-Knot® RC with Tape All-Suture Anchor
Y-Knot® RC All-Suture Anchor
CrossFT™ Knotless Suture Anchor
Y-Knot® Flex All-Suture Anchors
CrossFT™and GENESYS CrossFT™ Suture Anchor
PopLok® Knotless Suture Anchors – 3.5/4.5mm
HEAD | OFFICE |